GENERAL DESCRIPTION
HOLLY IS A DEVICE WHICH HAS BEEN SPECIALLY DESIGNED FOR DETECTING MICRO-PERFORATIONS IN IONIC EXCHANCE MEMBRANES. A TYPICAL DEFECT OF THESE MEMBRANES IS MICRO-PERFORATION DUE TO THEIR MOVEMENT WITHIN THE ELECTROLYZERS. THE IDENTIFICATION OF THE MICRO-PERFORATIONS TAKES PLACE VIA AN AUTOMATIC CYCLE WHICH NARROWS THE LOCATION OF THE MICRO-PERFORATION TO A RESTRICTED AREA AND USE A PROBE TO DEFINE ITS EXACT POSITION. HOLLY IS EQUIPPED WITH A DEPRESSED POROUS SURFACE WHICH RECEIVES THE MEMBRANE AND A FRAME WHICH IS ACTIVED BY FOUR PNEUMATIC CYLINDERS. INSIDE THE FRAME A SENSOR IS ACTIVATED BY TIMING BELTS, AND IS LOWERED ONTO THE MEMBRANE THANKS TO TWO PNEUMATIC CLINDERS, GUARANTEEING CONSTANT SPECIFIC PRESSURE. THE SYSTEM IS EQUIPPED WITH A THERMO-VENTILATION CYCLE WHICH DIMINISHES THE CHECKING TIME. THE MICRO-PERFORATIONS ARE IDENTIFIED BY MEANS OF ACOUSTIC AND/OR LUMINOUS SIGNALS LOCATED INSIDE THE AUTOMATIC SENSOR. A MANUAL SENSOR MAKED A PRECISE INDIVIDUATION OF THE MICRO-PERFORATION WHICH IS MARKED BEFORE BEING REPAIRED USING A WELNY WELDING DEVICE. THE MOVEMENT OF EACH INDIVIDUAL BOARD IS MANAGED FROM A SINGLE CONTROL PANEL LOCATED ON THE SIDE OF THE DEVICE.

TECHNICAL SPECIFICATION

POWER SUPPLY VOLTAGE
220V - 50 Hz
POWER ABSORBED
2.5 Kw
AUXILIARY VOLTAGE TO CONTROLS
24 VDC
LINE COMPRESSED AIR PRESSURE
min. 6 max 8 bar
COMPRESSED AIR CONSUMPTION
14 Nm³/h
VACUUM BENEATH MEMBRANE WITH MEMBRANE APPLIED
TYPICAL -0.7 bar
APPROX. HEIGHT OF WORK SURFACE
1.20 m

PERFORMANCE

CONTROLLABLE EXPANDED MEMBRANE SIZES
HOLLY-88
1310 x 820 mm *
HOLLY-175
1310 x 1570 mm *

HOLLY-250

1310 x 2460 mm *
HOLLY-350
1310 x 3000 mm *
MINIMUM DETECTABLE PERFORATION SIZE
" 100 MICRON
EXPLORATION LIMITS
UP TO 15 mm FROM INSIDE FRAME EDGE
TYPICAL PRESSURE OF SENSOR ON MEMBRANE
0.4 N/cm²
SENSOR SPEED
1 metre/minute
INTERMITTED ACOUSTIC ALARM INSURE PRESENCE OF PERFORATION AUTOMATIC STOPPED INSURE PRESENCE OF PERFORATION NONE STRESS ON THE MEMBRANE NO INSTALLATION TIME IS INVOLVED HOLLY GUARANTEES THAT YOUR MEMBRANE IS CHECKED COMPLETELY IN FEW MINUTE

USE PARAMETERS
LINE PRESSURE NO LOWER THAN 5 bar
SENSOR PRESSURE NO LOWER THAN 3 bar
VACUUM REACHED WITH FRAME SEALED AND MEMBRANE IN PLACE (DOWN FRAME) NO LOWER THAN -0.1 bar.

MEMBRANE TREATMENT BEFORE CHECKING
THE MEMBRANE MUST BE COMPLETELY WET BEFORE IT IS LOWERED ONTO THE POROUS SURFACE, SO AS TO GUARANTEE THE CORRECT WORKING DIMENSIONS. THE MEMBRANE MUST BE CLEARED OF ANY FOREIGN BODIES BEFORE BEING LOWERED ONTO THE POROUS SURFACE. HAVING LOWERED THE MEMBRANE ONTO THE POROUS SURFACE AND SEALED THE FRAME, DRY IT WITH A SPONGE OR PAPER TO REMOVE THE FILM OF WATER, THUS CREATING THE BEST WORKING CONDITIONS.


STEP-1:THE MEMBRANE IS POSITIONED FROM THE UP POSITION ON THE VACUUM PLANE

STEP-2: THE MEMBRANE REMAIN IN POSITION BY THE VACCUM PLANE

STEP-3: THE UPPER FRAME GO DOWN - THE SENSOR START TO TEST - STOPS NEAR THE PERFORATION - EMITTED AN ACOUSTIC SIGNAL -THE RELATIVE LAMP LIGHTS UP

STEP-4: THROUGHT A MANUAL PROBE THE OPERATION FIND THE EXACTLY POSITION OF THE PERFORATION

STEP-5: THE OPERATOR MARKS THE PERFORATION'S AREA

STEP-6: THE SENSOR FINISH ITS AUTOMATIC TEST AND GO TO END-STROKE

STEP-7: THE UPPER-FRAME GO IN UP-POSITION

STEP-8: THE OPERATOR REMOVETHE MEMBRANE TO REPAIR THE MARKER'S ZONE WITH WELNY MACHINE