GENERAL DESCRIPTION

THE DRYER, OF THE QUDRY'S SERIE, FOR COMPRESSED AIR, USE THE ADSORBING PROCESS WITH THE COLD REGENERATION.
A COMPRESSED AIR GOES IN AN OIL/MOISTURE PREFILTER, AFTER PASS IN ONE OF THE TWO TOWER SERIE THAT CONTAINS THE ADSORBENT MATERIAL WHERE DEPOSIT THE UMIDITY AND AT LAST ACROSS AN END FILTER WICH DETAIN EVENTUALLY SOLID POLLUTION AGAIN IN SUSPENSION.

AFTER A SET TIME THE COMPRESSED AIR COMES TURNED IN THE OTHER TOWER SERIE. IN THE FIRST TOWER SERIE COMES INTRODUCED NOW AIR DRY, TO DRIP BY SET NOOZLE BEFORE THE DRYER THAT PROVIDE TO TAKE AWAY THE UMIDITY PREVIOUSLY DEPOSITED.

AT ANY CYCLO OF TOWER EXCHANGE AN EXAUSTE VALVE PROVIDE TO RELEASE THE LIQUID INSIDE THE OIL/MOISTURE PREFILTER. THE AUTOMATIC CHANGE, OF THE TWO TOWER SERIE , MAKE THE SYSTEM COMPLETELY AUTONOMOUS. TWO SERIES OF TOWERS CONTAINS THE ADSORBENT MATERIAL ARE DISPOSED PARALLEL.

ON THE DOWN BACK SIDE THERE ARE :

  • INLET PORT OF THE AIR
  • COMPRESSED PRESSURE
  • OIL/MOISTURE PREFILTER SWITCHING VALVES
  • LIQUID EXAUSTE VALVE

ON THE DOWN FORWARD SIDE THERE ARE:

  • EXAUSTE VALVE OF REGENERATION AIR
  • EXAUSTE SILENCER

ON THE UP FORWARD SIDE THERE ARE:

MAIN PANEL WITH :

  • GAUGE INLET PRESSURE
  • GAUGE OUTLET PRESSURE
  • GAUGE RIGHT TOWER PRESSURE
  • GAUGE LEFT TOWER PRESSURE

    THE ELETTROPNEUMATIC PANEL WITH:

  • MAIN SWITCH OPEN SUPPLY VOLTAGE AND THE CYCLO START

    PLC FOR :

  • CYCLO OF DEHYDRHTYON
  • INPUT FOR MOISTURE AUTOMATIC EXAUSTE
  • DRIVING CYCLO ELETTROVALVE
  • SAFETY FUSE

SET NOOZLE FOR REGENERATION AIR

FEATURES

MODULAR STRUCTURE
SETTLEMENT TOWER WITH VOLUME ELEMENT
(EXEMPT FROM DEVICES CERTIFICATION IN PRESSURE): 14 dm ³
OIL/MOISTURE INLET FILTER: COALESCENT
OUTLET FILTER: TARGET 8 micron
MOISTURE AUTOMATIC EXAUSTE TEMPORIZED: 1 sec./ 18 min.
AIR CONSUPTION FOR REGENERATION ON THE NOMINAL FLOW : 14%
DEVICE OF REDUCE AIR REGENERATION CONSUPTION: PROPORTIONAL TO LINE PRESSURE INPUT CYCLO
ELETTROPNEUMATIC VOLTAGE: 220 V 50 60 Hz
ELECTRICAL POWER CONSUPTION: MAX 30 VA
ELECTRICAL PROTECTION:IP 65
MANUFACTURED: UNDER CE RULES

PERFORMANCE

  • MAX PRESSURE: 9 bar (130 psi)
  • DEW POINT: - 25° C (TO ATMOSFERIC PRESSURE)
  • MAX AIR COMPRESSED TEMPERATURE INLET: + 35° C
  • PRESSURE DROP TO INDICATE FLOW: bar 0.4 (5 PSI)

OVERAL DIMENSIONS
(Devices protected by international patents)

ALL RIGHT ARE LEGALLY PRESERVED, DIRITTI RISERVATI, RIPRODUZIONE PARZIALE VIETATA